• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Place of Origin: Beijing, China (Mainland)
  • Brand Name: Navipro
  • Model Number: F330
  • Type: capacitance
  • Measurement range: 100~1500mm
  • Material: Aluminium
  • Output: Analog or Digital
  • Media: Fuel,Ethanol,Gasolin
  • Power supply: 10-32V DC
  • Output Signal: 0-5V DC
  • Working Temperature: -40~85℃
  • Mounting: SAE 5 blot flange
  • User cut short: Yes

Packaging & Delivery

Packaging Details: Fuel level sensor with strong packed carton.
Overview

 

The DF330 is capacitance level sensor. The most advantage is to be cut short by user at field. It is applicable for measurement of liquid level,such as crude oil,diesel, gasoline and ethanol (special version).  

It is applicable for the close container or open container or pool or river.   As with RS485, it is easy to integrate into the embedded system or SCADA.

In order to realize remote monitoring, there are wireless module optional for DF330, including zigbee, Wifi, GPRS, 3G. Furthermore, GPS module is one optional for the DF330. 

 

  

Specification

 

Sensor length

100~ 1000mm (Other size negotiate)

Resolution

1mm

Power Supply

10-32V DC

Output Signal

0-5V DC/RS232/RS485

Working Temperature

-40 ~ 85℃

Material

Aluminum alloy

Media

diesel, biodiesel, gasoline (Not applicable to conducting medium )

Protection Rank

IP65

Mounting

flange

Wireless

Optional for zigbee, wifi, GPRS, UMTS.

 

Mechanical Drawing

System Diagram for  capacitive level sensor

 

Test Report

5.1 Device

            test sample ( length=10cm )                                                             test environment

5.2 Data

Below is linear test of 10cm length sensor.

  

Interface Definition

6.1 Analog Output

Pin 1: Red Line: V+, 

Pin 2: Blue Line: 0-5V DC Output

Pin 3: Black Line: GND

6.2 RS232 Output

Pin 1: Red Line: V+, 

Pin 2: Blue Line: RS232 Rx

Pin 3: Black Line: GND

Pin 4: Yellow Line: RS232 Tx

6.3 RS485 Output

Pin 1: Red Line: V+, 

Pin 2: Blue Line: RS485 A+

Pin 3: Black Line: GND

Pin 4: Yellow Line: RS485 B-

Calibration

Calibrator must couple with the sensor, and it has 12V/ 23A battery inside.

 

Red light is the power light. If the light isn't on when switch on, battery replacement is needed;

Green light is the calibration light. Full/ Empty button is showed in above picture.

                   

7.1 Adjustment of sensor length

Aluminum tube at the bottom can be shorter according to different requirements from customers. Steps are as follows:

  • Ø Customer specifies the sensor length according to the needs;
  • Ø Cut the unwanted part with steel saw;
  • Ø Get rid of the burrs and the debris at the cutting area with blade or a screwdriver to avoid short circuit.  
  • Ø Take down the filter unit, take out the plug, and assemble the plug in the aluminum tube, then assemble the filter.  

7.2 Calibration of the fuel level sensor

Calibration of the fuel sensor is calibration of the full level and empty level. The fundamental principle is to record a full value and empty value in the fuel sensor when tank is full and empty; defining the positions of fuel is full and empty in the tank. The electrical signal changes as the fuel level changes, calculating the height of the fuel level.

Note: when the fuel sensor becomes shorter, it shall be re-calibrated. Calibration to empty level and full level is related to the medium and the fuel level, instead of volume of the tank, so this operation can be operated in room (make a container, full filled with diesel, simulation of the tank). Calibration of full level shall go first, then the empty level, or else, it is impossible for the sensor to enter the

setting mode.

7.2.1. Calibration of full level

Full fill the tank, put sensor into the tank, wait for about 30s till the aluminum tube of the sensor is full of fuel, then press the “F” button on the calibrator for more than 10 seconds, During pressed down, the green led will flash.     

7.2.2. Calibration of the empty level

Take the sensor out of the tank; put it outside of the tank. When all the fuel flows out of the sensor, press the “E” button for more than 10 seconds , the green LED light flash one or two times, it indicates that calibration enters empty level mode. 

7.2.3. Calibration completion

Disconnect the calibrator after calibration is done. Connect Pin 1 and Pin 3 on sensor with power, calibration becomes effective when sensor is power on.

Note: During the calibration, keep the calibrator on!!!

7.2.4. Inspection

When calibration of the full level and empty level is done, inspect the output signal of the sensor:

Full level: V out is 5V

1/2 level: V out is 2.5V;

Empty level: V out is 0V.

If RS232 or RS485, the output is related to the level.

 

Installation

Installation

If  replace original sensor on vehicle, please firstly take off the original sensor, then go to next step. If install new sensor, directly go to next step.

8.1  Preparation

Please check  whether the sensor, accessories and tools are ready, including flange, rubber seal, O ring, screw(customer prepare), electric drill (customer prepare).

8.2 Drilling Holes

According to flange size, use electric drill to work out holes for sensor and screws. 

  

8.3 Mounting

Put O ring at bottom of sensor, then connect with flange and fasten.          

8.4 Sensor mounting

Put rubber seal on fuel tank, mount sensor, then fasten screws. 

8.5 Connect lines

According to above Connecting Diagram,Connect sensor lines with the device or equipment. 

  

Protocol

Protocol (for RS232/485/wireless version)

The default baud rate is 9600bps, one start bit, eight data bit, one stop bit, no checksum bit.

9.1 Read Level AD Value

Request: From device to sensor.

ASCII: $!RY0151

Hex: 24  21  52 59 30  31  35  31  0D 0A

$! is header, RY is command, 01 is sensor id, 51 is end.

 

Reply: From sensor to device

ASCII: *CFV0100FA32B6 

Hex: 2A  43  46  56  30  31  30  30  46 41  33  32  42 36  0D  0A 

* is header, CFV is reply command. 01 is sensor id. 00FA32 is AD value for level. 00 is the padding to fulfill 6 bytes of data section required. FA32 is the level AD value.  Level 0%~100%  equals with 000000~00FFFF. 

9.2 Read Level Percent

Request: From device to sensor.

ASCII: $!DO0139 

Hex: 24  21 44  4F  30  31  33  39  0D 0A

$! is header, DO is command, 01 is sensor id, 39 is end.

 

Reply: From sensor to device

ASCII: *RFV01000.0198 

Hex: 2A  52 46 56  30  31  30  30  30 2E   30 31 39 38  0D  0A

* is header, RFV is reply command. 01 is sensor id.  000.01 is the level value in percent. Max is 100.00. 

9.3 Set Sensor ID

Request: From device to sensor.

ASCII: $!ID0133 

Hex: 24  21 49 44  30  31  33  33  0D 0A

$! is header, ID is command, 01 is sensor id, 33 is end.

 

Reply: From sensor to device

ASCII: *SID01OKOKOK39  or *SID01NONONO42 

Hex: 2A  53  49 44 30  31  4F   4B  4F  4B  4F   4B 33  39  0D  0A 

or 2A  53  49 44 30  31  4E   4F  4E  4F   4E   4F   34  32  0D  0A

* is header, SID is reply command. 01 is sensor id.  OKOKOK means succeed. NONONO means failed.

Naming Rules & Clarification

10.1 Naming Rules

10.2 Clarification

As the DF330 can be cut short by user,  the user should select the length which is longer and around to times of 100. For example, if the tank height is about 550mm, the user should remark 600mm while place the order. 

Package

Part List

NO.

Item

Quantity

Remark

1

Level sensor

1

 

2

Rubber blanket

1

   

3

Retaining screw

6

  

4

Manual

1

 

 

100*30*30cm, for 20 unit/box

 

Certifications

 

Warranty

      We warrants this quality product to be free of defects in material and workmanship for a period of one 

year from the date of purchase. During the period, we will repair or replace the product at no charge for 

parts or labor. But the shipment fee will be shared by the buyer (one party 50%).

     The time period of this warranty starts from the date of the original purchase and expires on the first 

anniversary date of purchase.

      No express or implied warranty is made for any defects in this product which result from accident, 

abuse, misuse, failure to operate the product in accordance with relevant instructions, neglect, immersion 

in or exposure to chemicals or liquids, extremes of climate, fungus, excessive wear and tear/cosmetic 

damage and defects resulting from other extraneous causes such as unauthorised disassembly, repair or 

notification.

     This warranty shall not extend to any incidental or consequential damages arising from the purchase, 

use or inability to use this product. 

     The laws of some countries and some States thereof do not allow the limitation of incidental or consequential

 damages, so the above limitation or exclusion may apply to you.

 

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
Trade Assurance
China (Mainland) | Trading Company
Transaction Level:
Supplier Assessments:
16 Transactions 10,000+
The supplier’s transactions conduted via Alibaba.com in the past 6 months.